top of page
Writer's pictureDarren Sciberras

Safety Bulletin - Block off Plates

Criticality – Serious


Such failure could cause an accident on track due to unexpected power loss and a bike behind could be caught unaware Problem: short circuit in one of the ignition coil wires


The wire was part of the aftermarket blip assist system and could be the same on a quickshift system


We have concluded 2 root causes


o The smog block off plate that was installed had very sharp edges. This is becoming more an more common with cheaper aftermarket components. Over 50% of smog block off plates we see have this issue.


o The aftermarket blip system had the wires exposed for too long a section

· The above 2 issue lead to the wires insulation being slowly cut away resulting in the short



Recommended Rectification


Check for any sharp edges on block off plates or similar items where any wiring may come into contact. Chamfer edges and remove sharpness


Tape up or heat shrink an extra layer of protection around such exposed wires


Cable tie wiring under airbox as neatly away as possible






286 views

Recent Posts

See All
bottom of page